Consider a portable water analyzer that adds a fraction of a milliliter of reagent to each sample, running for days on a small battery pack. Or a laboratory instrument that feeds a stain, a buffer or a nutrient solution at a steady trickle. In both cases, the pumping requirement is tiny: a flow measured in tenths of a milliliter per minute, from a pump that fits in the palm of a hand and draws very little power. The Paquin P162 Mini Peristaltic Pump targets that niche, delivering anywhere up to 2 mL/min from a 13 g body with power consumption of 2 W or less.
Micro-flow delivery in a 13 g package
The P162 pairs a micro brush DC gear motor with a two-roller pump head. Its main body is about 40 mm long, with a 20 mm diameter pump head, and it mounts through a 15 × 13.5 mm opening. An optional rubber mounting plate is available. Rollers squeeze the tube from the outside, so the liquid is only ever in contact with the tubing itself. Switching to a different fluid usually means fitting fresh tubing, not reworking the pump.
Three supply voltages are offered, 3, 6 and 12 VDC, so the pump can run from a small battery, a USB-derived rail or a standard 12 V supply.
Choosing a micro peristaltic pump flow range
At these volumes, tube size sets the flow. The P162 is ordered in one of three flow ranges, each matched to a specific tube:
| Flow range option | Flow (mL/min) | Tube size (ID × OD, mm) |
|---|---|---|
| A | 0 – 0.3 | 0.5 × 1.5 |
| B | 0.2 – 1.2 | 1 × 2 |
| C | 0.6 – 2 | 1.5 × 2.5 |
The ranges overlap slightly, which helps when an application sits near a boundary. Treat the quoted ranges as reference values. They come from bench tests with clean water at 23°C under near-ideal conditions, so a thicker liquid, a warmer cabinet or extra back-pressure in the line will shift the actual delivery. Where accuracy matters, hold those conditions as steady as possible and verify the flow in the finished product.
Simple by design: fixed-rate operation
The P162 is a power-on pump. Apply voltage and it runs at a constant speed, delivering a steady, fixed flow; remove power and it stops. There is no driver board to configure and no control signal to generate. That simplicity suits products where the dose is set by run time, for example a controller that switches the pump on for a set number of seconds, or where a slow, continuous feed is all that is needed.
Applications that require adjustable speed, reversing or Modbus control are better served by a stepper-driven pump such as the P408, with flow options up to 420 mL/min.
Setting a dose by run time
With a fixed-rate pump, the delivered volume is simply flow multiplied by time. As a nominal example, a pump delivering 0.3 mL/min runs for 20 seconds to deliver about 0.1 mL. One delivering 1.2 mL/min supplies roughly 1 mL in 50 seconds. Because actual flow varies with the fluid, the tubing and the installation, the practical approach is to calibrate in place: run the pump for a known time, measure the volume delivered, and set the controller's run time from that result. Recalibrate when the tubing is replaced or the fluid changes.
Tubing and connectors
Two tubing materials can be ordered with the pump, along with the tubing length in whole meters:
- BPT: listed as FDA, REACH, NSF, RoHS and USP Class VI; rated -58 to 275°F (-50 to 135°C); can be sterilized by ethylene oxide, autoclave or gamma radiation.
- Silicone: listed as FDA, REACH, NSF, RoHS and USP Class VI, food grade (SGS) and medical grade (FDA); rated -76 to 392°F (-60 to 200°C); can be sterilized by autoclave.
Each pump is ordered with either straight or right-angle (elbow) fittings, and the datasheet lists a range of connector sizes for matching the pump to downstream tubing.
Applications
- Medical and laboratory devices
- Environmental monitoring instruments
- Food and beverage equipment
- Consumer appliances
- Industrial automation
Key specifications (snapshot)
| Parameter | Value |
|---|---|
| Flow rate | 0–2 mL/min, in three ranges |
| Motor | Micro brush DC reduction (gear) motor |
| Control | Power-on operation; constant speed, fixed flow |
| Supply voltage | 3, 6 or 12 VDC |
| Power | ≤2 W |
| Rollers | 2 (standard) |
| Tubing | BPT or silicone |
| Working temperature | 32 to 113°F (0 to 45°C) |
| Working humidity | <85% RH |
| Weight | 13 g |
Dimensions, the installation cut-out and the full connector and tube size tables are in the P162 datasheet (PDF).
Bring your dosing requirement to Paquin
Paquin's pump collection covers flows from fractions of a milliliter to more than two liters per minute, so the right size is usually close at hand.
A target flow and a fluid are enough to start. From the P162 product page, let us know the flow you need, the liquid, your available supply voltage and the tubing you plan to use, and Paquin will confirm the flow range and connector options and return a quotation.
For new pump, sensor and valve introductions, follow Paquin on LinkedIn.