How much humidity sensor does a building really need? For a server room, a museum gallery, a warehouse or a hospital air handler, the answer is usually a dependable reading of relative humidity and temperature, delivered in a format the building automation system already understands. It also needs to fit neatly into a duct or equipment space. The Paquin P163 Humidity & Temperature Transmitter is built around that brief. It is a compact probe-style humidity and temperature transmitter with RS485 Modbus or 0–10 VDC outputs, a digital sensing probe and an IP65 rating, sized for HVAC and building monitoring rather than harsh process duty.
A probe-style humidity and temperature transmitter for buildings
The P163 combines a digital relative humidity sensor and a digital temperature sensor in a slim polycarbonate probe, 15 mm in diameter and about 104 mm long. It measures relative humidity across the full 0–100% RH range, with an accuracy of ±3% RH at 68°F (20°C) and 60% RH. Temperature accuracy is ±0.54°F (±0.3°C) at 68°F, and the datasheet's accuracy curve shows this widening gradually toward the ends of the operating range.
The transmitter is rated for working environments from -40°F to 185°F (-40°C to 85°C) at 5–95% RH, non-condensing. Its digital probe is designed for good long-term stability and resistance to electrical interference.
Two outputs, chosen for each measurement
Humidity and temperature outputs are specified separately when the P163 is ordered, so each signal suits the inputs available on site:
- RS485 Modbus: both readings are available over a single two-wire data connection, suitable for building automation and monitoring networks.
- 0–10 VDC (3-wire): separate analog signals for humidity and temperature, for controllers and BMS inputs that expect voltage.
For voltage-output versions, the temperature span is chosen when ordering: 32 to 122°F (0 to 50°C), -4 to 140°F (-20 to 60°C), or a range specified by the customer. Every version runs on 12–36 VDC, with protection against overvoltage and reversed polarity.
Modbus or 0–10 VDC: choosing the output
The right output usually depends on how many measurement points a project has and what the receiving system expects. Modbus suits projects with many sensors: each P163 shares the same pair of data wires, readings arrive as digital values with no scaling to set up, and additional sensors can be added to the bus later. A 0–10 VDC output suits smaller installations or controllers with spare analog inputs. Wiring is simple, but each signal needs its own conductor and its own input, and the controller must be scaled to the temperature span chosen when ordering. When a building already has a Modbus network, the digital version is generally the more economical choice to install.
Straightforward installation
The P163 is designed for mounting through a duct wall or equipment panel using a mounting flange. Installation follows five steps:
- Drill the installation hole.
- Fit the mounting flange.
- Tighten the fixing screws.
- Insert the transmitter and adjust it to the required depth.
- Tighten the tapping screw to hold it in position.
Wiring is color-coded. On RS485 versions, red and black carry power, and green and white carry the 485A and 485B data lines. On voltage versions, red and black carry power, green carries the humidity signal and white the temperature signal.
Getting reliable readings
Like any humidity sensor, the P163 performs best when it measures air that represents the space. The datasheet gives clear guidance:
- Install away from heat sources, cold sources and direct sunlight.
- Do not use the P163 where oil contamination, organic solvents or corrosive gases are present. Long exposure to high concentrations of chemical gases can shift the readings.
- In dusty environments, clean the probe's filter membrane regularly.
- When the transmitter is out of service for long periods, store it somewhere dry.
Where the air is hot, pressurized or chemically aggressive, consider Paquin's industrial-grade A & B Series instead, which offers versions for those conditions.
Applications
- HVAC systems
- Data centers
- Warehouses
- Commercial buildings and parking garages
- Museums
- Laboratories, schools and hospitals
Key specifications (snapshot)
| Parameter | Value |
|---|---|
| Humidity range / accuracy | 0–100% RH / ±3% RH at 68°F (20°C) and 60% RH |
| Temperature accuracy | ±0.54°F (±0.3°C) at 68°F (20°C) |
| Sensors | Digital humidity and temperature |
| Outputs | RS485 Modbus or 0–10 VDC (3-wire), selected per measurement |
| Temperature span (voltage output) | 32–122°F, -4–140°F, or customer specified |
| Supply voltage | 12–36 VDC, overvoltage and reverse-polarity protected |
| Working environment | -40 to 185°F (-40 to 85°C), 5–95% RH non-condensing |
| Housing / protection | Polycarbonate (PC) / IP65 |
| Probe size | Ø15 mm x approx. 104 mm |
For the part-number builder, the accuracy curve and both wiring options, see the P163 datasheet (PDF).
Specify a P163 for your building
Three choices define a P163: humidity output, temperature output and, for voltage versions, the temperature span. Request a quote through the P163 product page, telling us where it will be installed and what your BMS or controller accepts, and we will reply with the matching configuration and a price.
See Paquin's newest humidity, temperature and HVAC sensors on LinkedIn.